Insulation sheet thickness measurement standard:
More than 5 different points shall be randomly selected on the whole insulating board for thickness measurement and inspection. It can be measured with a thousand heart and liver or an instrument with the same accuracy. The accuracy of the micrometer shall be within 0.02mm, the diameter of the measuring drill shall be 6mm, the diameter of the plane presser foot shall be (3.17 ± 0.25) mm, and the presser foot shall be able to exert a pressure of (0.83 ± 0.03) n. The insulating pad should be laid flat so that the micrometer measurement is smooth.